在赣州酒店晚上怎么叫服务

Automatic thermal desorption instrument

Automatic 10 / 20 bit once thermal desorption instrument: autotds-iv

Auto tds-iv full-automatic thermal desorption instrument is a 10 bit / 20 bit automatic one-time thermal desorption instrument, which can automatically complete the desorption and sample injection back blowing process of 10 / 20 adsorption tubes in linkage with chromatography.

  • model: AutoTDS-IV

Methods autotds was recommended -IV Type a full automatic thermal desorption instrument

Brief introduction of the instrument:

AutoTDS-IV The model is a 10 bit / 20 bit full-automatic one-time thermal desorption instrument, which can automatically complete the desorption and injection back blowing process of 10 / 20 adsorption tubes in linkage with chromatography. It is applicable to GB 50325-2010 code for indoor environmental pollution control of civil building engineering.

Working conditions:

l     Power supply: 220 VAC ± 22 VAC, 50 Hz ± 0.5 Hz

l     Back blowing carrier gas pressure: ≤ 0.4MPa

l     Ambient temperature + 5 ~ 35 ℃

l     Relative humidity: ≤ 85%

Technical parameters:


l   Power: < 600VA

l   First desorption temperature: fifty thirty-eight zero The control accuracy is ± 1 ℃

l   Pipeline heating temperature: 50 two hundred The control accuracy is ± 1 ℃

l   Timing range: one second fifty-nine minute fifty-nine second

l   Timing error: <0.1%

l   Sample grade: 10 bits / 20 bits

l   Pressure resistance of gas circuit: > 0.4MPa

l   Two channels: synchronous output signal one two Second switching value

l   Instrument dimensions: high * wide * long     500mm *310mm*650mm ten Bit)

500mm*400mm*610mm twenty Bit)

l   The weight of the instrument is about: 30kg


Main features:

l   Strong general performance It can be used with any brand gas chromatograph( GC )And( GC-MS )In combination.

l   Easy to operate, easy to use, full software control, high degree of automation All the operation and control are completed by the control software, so the sample has good repeatability; Super large in the host Touch LCD screen Design, can track temperature and operation command in the whole process.

l   Synchronous interface is provided to start chromatography and workstation at the same time of injection.

l   All pipelines and six way valves can be heated at controlled temperature to eliminate the cold point of the system and reduce sample loss.

l   With automatic leak detection and fault alarm function of sample tube : before testing each sample, it can automatically check whether the sample tube and system gas path are installed properly.

l   The sample pipeline is treated with silylation inert treatment of stainless steel pipe to reduce pollution residue.

 

 


Methods autotds was recommended -IV. working conditions of full-automatic 10 / 20 bit primary thermal desorption instrument:

  • Power supply: 220 VAC ± 22 VAC, 50 Hz ± 0.5 Hz

  • Back blowing carrier gas pressure: ≤ 0.4MPa

  • Ambient temperature + 5 ~ 35 ℃

  • Relative humidity: ≤ 85%


Technical parameters of autotds - Ⅳ fully automatic 10 / 20 bit primary thermal desorption instrument:

  • Power: < 600VA

  • First desorption temperature: 50 ~ 380 ℃, control accuracy ± 1 ℃

  • Pipeline heating temperature: 50 ~ 200 ℃, control accuracy ± 1 ℃

  • Timing range: 1 second ~ 59 minutes 59 seconds

  • Timing error: < 0.1%

  • Sample grade: 10 bits / 20 bits

  • Pressure resistance of gas circuit: > 0.4MPa

  • Synchronous signal output: two 1-2 second switching values

  • Instrument dimensions: height * width * length
    500mm * 310mm * 650mm (10 bits)
    500mm * 400mm * 610mm (20 bits)

L. the weight of the instrument is about 30kg


Reliable manufacturers in Beijing Methods autotds was recommended -Ⅳ automatic 10 / 20 bit one time thermal desorption instrument

10 bit random list

Serial number

name

Company

number

one

AutoTDS-IV ten Full automatic thermal desorption instrument

platform

one

two

5A Safety management

only

five

three

power cord

root

one

four

Synchronous signal line

root

one

five

Ф 3 conical gasket

individual

five

six

Ф 1.5 conical gasket

individual

five

seven

O Ring 10 * 2.4

individual

fifty

eight

Injection spacer

individual

twenty-five

nine

Two links

set

two

ten

tee

set

one

eleven

Four links

set

one

twelve

∮ 1.6 stainless steel pipe

root

one

thirteen

Adsorption pipe joint

individual

twenty

fourteen

∮ 1.3 copper pad and needle

set

ten

fifteen

Imported Tenax adsorption tube

branch

one

sixteen

certificate

share

one

seventeen

instructions

share

one

eighteen

Warranty bill

share

one


20 bit random list

Serial number

name

Company

number

one

AutoTDS-IV Type( twenty Full automatic thermal desorption instrument

platform

one

two

5A Safety management

only

five

three

power cord

root

one

four

Synchronous signal line

root

one

five

Ф 3 conical gasket

individual

five

six

Ф 1.5 conical gasket

individual

five

seven

O Ring 10 * 2.4

individual

one hundred

eight

Injection spacer

individual

fifty

nine

Two links

set

two

ten

tee

set

one

eleven

Four links

set

one

twelve

∮ 1.6 stainless steel pipe

root

one

thirteen

Adsorption pipe joint

individual

forty

fourteen

∮ 1.3 copper pad and needle

set

ten

fifteen

∮ 3 PTFE tube

root

one

sixteen

Imported Tenax adsorption tube

branch

two

seventeen

Product description

share

one

eighteen

certificate

share

one

nineteen

Warranty bill

share

one