在赣州酒店晚上怎么叫服务

Industry specific thermal desorption

Determination of soil by Taiyuan cold trap thermal desorption instrument

Auto TDS vPro is a 24 bit low temperature secondary thermal desorption instrument with shunt function, which can store multiple operation methods.

  • model:

Methods autotds was recommended -VPro automatic pyrolyzer
(equipped with 24 bit, secondary low temperature capture and desorption function)
 

Determination of soil by Taiyuan cold trap thermal desorption instrument Introduction:
The tds-24 full absorption pyrolyzer is a multi-function automatic pyrolyzer.
In addition, the temperature of the desorbing tube can be set by using the temperature of the desorbing tube, the temperature of the second desorbing tube, and the temperature of the desorbing tube can be set automatically At the same time, the chromatograph and workstation can be started at the same time.  

 
Determination of soil by Taiyuan cold trap thermal desorption instrument Working conditions:
Power supply: 220 ± 22vac, 50 ± 0.5Hz (power line ensure reliable grounding, case grounding)
Back blowing carrier gas pressure: ≤ 0.4MPa
Ambient temperature: 35 ℃~ 5 ℃
Relative humidity: ≤ 85%

 
Determination of low level regulated phthalates in PVC plastics by 24 position thermal desorption analyzer Technical parameters:

  • Power: < 900va

  • 24 bit / sample

  • Temperature control range:
    One time desorption: room temperature ~ 400 ℃, control accuracy ±1℃ 
    Second desorption: Room temperature ~ 400 ℃, heating rate > 3000 ℃ / min
    piping: Room temperature ~ 220 ℃, control accuracy ± 1 ℃
    Cold trap: minimum - 35 ℃ (room temperature: 20 ℃)

  • One time desorption shunt and no shunt are available

  • Timing range: 1 second ~ 59 minutes 59 seconds

  • Timing error: < 0.1%

  • Pressure resistance of gas circuit: > 0.4MPa

  • Flow regulation range: 0-300 ml / min

  • Synchronous signal output: two 1-2 second switching values

  • Overall dimensions: height * width * length 460mm * 370mm * 700mm

  • The weight of the instrument is about 35kg


Automatic 24 bit low temperature secondary thermal analyzer Main features:


  1. Strong general performance: it can be combined with any brand gas chromatograph (GC) and (GC-MS) to realize the interconnection of control information.  

  2. Simple operation, easy to use, software control, high degree of automation: just put the sample tube into the thermal desorption instrument, all operations and control are completed by the control software, so the sample repeatability is good; the design of large touch LCD screen in the host can track the temperature and operation command in the whole process.

  3. The system can store up to 10 running methods.

  4. Synchronous interface is provided to start chromatography and workstation at the same time of injection.

  5. Electronic flow display, purge flow and back flow

  6. The lowest refrigeration temperature is - 35 ℃ (room temperature is 20 ℃), which can meet most of the requirements of low temperature enrichment.  

  7. The trap is heated by direct resistance, and the heating rate is more than 3000 ℃ / min.

  8. All pipelines and six way valves can be heated at controlled temperature to eliminate the cold point of the system and reduce sample loss.

  9. Split / no split, one-time desorption can be switched between split and no split, the split ratio is manually adjusted.  

  10. With sample tube automatic leak detection and fault alarm function: before testing each sample, it can automatically check whether the sample tube and system gas path are installed properly.  

  11. The sample pipeline is treated with silylation inert treatment of stainless steel pipe to reduce pollution residue.

  12. It is directly connected to the GC carrier gas path without occupying the injection port.

  13. No pneumatic components, no need to drive air source.

Automatic 24 bit low temperature secondary thermal analyzer

Random list

Serial number

name

Company

number

one

Methods autotds was recommended -VPro Type( twenty-four Full absorption pyrolyzer

platform

one

two

5A Safety management

only

five

three

power cord

root

one

four

Synchronous signal line

root

one

five

Ф 3 conical gasket

individual

five

six

O Ring 10 * 2.4

individual

one hundred

seven

Ф 1.5 conical gasket

individual

five

eight

Injection spacer

individual

fifty

nine

Two links

set

two

ten

tee

set

one

eleven

Four links

set

one

twelve

∮ 1.6 stainless steel pipe

rice

one point five

thirteen

Adsorption pipe joint

individual

fifty

fourteen

∮ 1.3 copper pad and needle

set

ten

fifteen

∮ 3 PTFE tube

individual

one

sixteen

Sealing ring of trap pipe

individual

two

seventeen

Imported Tenax adsorption tube

branch

five

eighteen

Product description

share

one

nineteen

certificate

share

one

twenty

Warranty bill

share

one