Automatic purge and trap device

Full automatic purge and trap instrument - Beijing steadfast PTC - I

Ptc-i purge and trap is a fully automatic purge and trap with electronic cold trap

  • model: PTC-Ⅰ

fully automatic National standard purge and capture instrument Brief introduction of the instrument:

Ptc-i purge and trap is a full-automatic purge and trap with an electronic cold trap: helium / nitrogen is used as purge gas, which is injected into the sample solution for bubbling; under the continuous air blowing, the volatile components in the sample escape with the purge gas, and are concentrated by a capture device with adsorbent; after a certain purging time, the purge gas is turned off, and the six components are switched off Through the valve, the trap pipe is connected to the carrier gas path of GC. At the same time, the trap pipe is heated rapidly to decompose and absorb the captured sample group, and then enter into GC with carrier gas for analysis. Combined with GC or GC / MS, it can be widely used in environmental analysis, such as the analysis of organic pollutants in drinking water or wastewater, and the analysis of volatile compounds (such as odor components) in food.


Automatic purge and trap main features

  • Strong general performance: it can be combined with any brand gas chromatograph (GC) and (GC-MS);

  • Therefore, it is easy to control the temperature in the whole process by the software, and the temperature can be controlled by the software.

  • The lowest refrigeration temperature is - 30 ℃ (room temperature is 20 ℃), which can meet most of the requirements of low temperature enrichment.

  • The trap was heated by direct resistance, and the heating rate was more than 2400 ℃ / min.

  • The built-in foam sensor can detect the foam in the purge tube to prevent contamination of the sample path and protect the entire analysis system.

  • The trap is separated from the purge tube to reduce cross contamination between samples. During the blowback cycle, compounds blown out of the trap will not flow into the purge tube.

  • The effect of water vapor on GC and GC / MS is greatly reduced.

  • All pipelines and six way valves can be heated at controlled temperature to eliminate the cold point of the system and reduce sample loss.

  • Synchronous interface is provided to start chromatography and workstation at the same time of injection

fully automatic National standard purge and capture Instrument technical parameters
Temperature of purging pipe: room temperature ~ 100 ℃, control accuracy ± 1 ℃
Cold trap (electronic semiconductor refrigeration) temperature: the minimum cooling temperature can reach - 30 ℃
The desorption temperature of trap: 150-380 ℃, heating rate > 2400 ℃ / min; drop from 250 ℃ to 35 ℃ in 90 seconds
Heating temperature of pipeline: 50 ~ 220 ℃, control accuracy ± 1 ℃
Heating temperature of dehydrator: room temperature ~ 350 ℃
Glass purging pipe: 5ml purging pipe (standard configuration); 25ml purging pipe (optional)
Size of trap: stainless steel, Φ 3mm × 25mm × 0.1mm
Flow rate: 150ml-10min
Maximum power: < 800VA
Timing range: 1 second to 99 minutes and 59 seconds
Timing error: < 0.1%
Pressure resistance of gas circuit: > 0.4MPa
Synchronous signal output: two-way 1-2 second switching value
External dimension of instrument: height * width * length: 500mm * 320mm * 500mm
Weight: About 30kg


Automatic purge and trap Working conditions
Power supply: 220 VAC ± 22 VAC, 50 Hz ± 0.5 Hz
Back blowing carrier gas pressure: ≤ 0.4MPa
Environment temperature: 5 ~ 35 ℃
Relative humidity: ≤ 85%

label: Purge trap